# SILCARP Master Wire-by-Wire Electrical Schematic Bible
**Document ID:** `SILCARP-ELEC-SCHEM-001`  
**License:** CERN-OHL-S v2 / CC BY-SA 4.0  
**Status:** Approved Engineering Specification  

---

## 1. Electrical Architecture Overview

The SILCARP electrical system strictly separates:
1. **High Voltage Traction Circuit (72V DC, isolated):** Completely floating from chassis ground. Monitored continuously by Bender A-ISOMETER isolation monitor ($> 500\,\Omega/\text{V}$ required, $> 2\text{ M}\Omega$ actual).
2. **Low Voltage Auxiliary Circuit (12V DC, negative chassis ground):** Powered by an isolated $72\text{V} \to 13.8\text{V}$ 30A DC-DC converter with a small $12\text{V}$ 5Ah LiFePO4 buffer battery.
3. **Sensor & Signal Ground (Clean Reference):** Dedicated return lines for analog sensors directly back to the VCU to prevent ground-loop offsets.

---

## 2. ZombieVerter VCU Delphi 56-Pin Master Pinout

The **ZombieVerter VCU v2** uses an OEM automotive Delphi 56-pin sealed header (Tyco / Delphi Micro-Pack 100/120 series):

```
       Delphi 56-Pin Header Layout (Front View, Keyways Up)
  ===================================================================
  Row A: [A1]  [A2]  [A3]  [A4]  [A5]  [A6]  [A7]  [A8]  [A9]  [A10] [A11] [A12] [A13] [A14]
  Row B: [B1]  [B2]  [B3]  [B4]  [B5]  [B6]  [B7]  [B8]  [B9]  [B10] [B11] [B12] [B13] [B14]
  Row C: [C1]  [C2]  [C3]  [C4]  [C5]  [C6]  [C7]  [C8]  [C9]  [C10] [C11] [C12] [C13] [C14]
  Row D: [D1]  [D2]  [D3]  [D4]  [D5]  [D6]  [D7]  [D8]  [D9]  [D10] [D11] [D12] [D13] [D14]
  ===================================================================
```

| Pin | Function Name | Direction | Signal Type | Target Component / Circuit | Wire Color & Gauge |
| :--- | :--- | :--- | :--- | :--- | :--- |
| **A1** | `+12V_PERMANENT` | Input | +12V Constant | Battery 12V Buffer via Fuse F1 (5A) | RED $1.0\text{ mm}^2$ |
| **A2** | `+12V_IGNITION` | Input | +12V Switched | Key Switch "RUN" position via Fuse F2 | RED/WHT $0.75\text{ mm}^2$ |
| **A3** | `GND_POWER` | Ground | 0V Chassis | Central Star Ground Stud | BLK $1.5\text{ mm}^2$ |
| **A4** | `GND_POWER` | Ground | 0V Chassis | Central Star Ground Stud (Redundant) | BLK $1.5\text{ mm}^2$ |
| **A5** | `CAN1_H` | I/O | CAN High | Main Powertrain CAN Bus (500 kbps) | YEL/BLK $0.5\text{ mm}^2$ (Twisted) |
| **A6** | `CAN1_L` | I/O | CAN Low | Main Powertrain CAN Bus (500 kbps) | GRN/BLK $0.5\text{ mm}^2$ (Twisted) |
| **A7** | `CAN2_H` | I/O | CAN High | Dedicated BMS / Battery CAN Bus | YEL/RED $0.5\text{ mm}^2$ (Twisted) |
| **A8** | `CAN2_L` | I/O | CAN Low | Dedicated BMS / Battery CAN Bus | GRN/RED $0.5\text{ mm}^2$ (Twisted) |
| **B1** | `POT1_THROTTLE` | Input | 0.5V–4.5V Analog | Throttle Pedal Hall Sensor 1 | BLU/WHT $0.5\text{ mm}^2$ |
| **B2** | `POT2_THROTTLE` | Input | 4.5V–0.5V Analog | Throttle Pedal Hall Sensor 2 (Inverse) | BLU/YEL $0.5\text{ mm}^2$ |
| **B3** | `+5V_SENSOR_REF` | Output| +5.0V Regulated | Clean Reference to Pedal & Brake Transducer | ORG $0.5\text{ mm}^2$ |
| **B4** | `GND_SENSOR` | Ground | 0V Sensor Return| Clean Ground to Pedal & Brake Transducer | BRN $0.5\text{ mm}^2$ |
| **B5** | `BRAKE_PRESSURE` | Input | 0.5V–4.5V Analog | Hydraulic Brake Transducer (0–100 bar) | VIO/WHT $0.5\text{ mm}^2$ |
| **B6** | `DI_FORWARD` | Input | +12V Digital | Gear Selector "Drive (D)" Switch | GRY $0.5\text{ mm}^2$ |
| **B7** | `DI_REVERSE` | Input | +12V Digital | Gear Selector "Reverse (R)" Switch | WHT $0.5\text{ mm}^2$ |
| **B8** | `DI_DOOR_AJAR` | Input | +12V Digital | Front Door Latch Series Microswitches | BLU/BLK $0.5\text{ mm}^2$ |
| **B9** | `DI_HANDBRAKE` | Input | Pull-to-GND | Mechanical Handbrake Lever Switch | BRN/WHT $0.5\text{ mm}^2$ |
| **B10**| `DI_BRAKE_SWITCH`| Input | +12V Digital | Brake Pedal Travel Limit Switch | RED/BLU $0.5\text{ mm}^2$ |
| **C1** | `OUT_MAIN_POS` | Output| Low-Side Switch | Main Contactor (+) Economizer Coil | BLK/RED $0.75\text{ mm}^2$ |
| **C2** | `OUT_MAIN_NEG` | Output| Low-Side Switch | Main Contactor (-) Economizer Coil | BLK/BLU $0.75\text{ mm}^2$ |
| **C3** | `OUT_PRECHARGE` | Output| Low-Side Switch | Precharge Contactor Relay Coil | BLK/YEL $0.75\text{ mm}^2$ |
| **C4** | `OUT_BRAKE_LIGHT`| Output| High-Side (+12V)| Brake Light Relay (K3) Trigger | GRN/WHT $0.75\text{ mm}^2$ |
| **C5** | `OUT_REVERSE_LT`| Output| High-Side (+12V)| Reverse Light Relay (K4) Trigger | WHT/BLK $0.75\text{ mm}^2$ |
| **C6** | `OUT_COOLING_PUMP`|Output| High-Side (+12V)| VESC Inverter Coolant Pump Relay | BLU/RED $0.75\text{ mm}^2$ |
| **C7** | `OUT_PTC_HEAT` | Output| High-Side (+12V)| 72V PTC Heater Solid State Relay | ORG/BLK $0.75\text{ mm}^2$ |
| **D1** | `VESC_ENABLE` | Output| +12V Digital | Inverter Ignition Run Pin (VESC EN) | YEL $0.75\text{ mm}^2$ |
| **D2** | `AVAS_SPEAKER` | Output| PWM Tone | Pedestrian Alert Sounder (0–20 km/h) | VIO $0.5\text{ mm}^2$ |

---

## 3. Cooper Bussmann 15300 RTMR Fuse & Relay Assignment

The **Cooper Bussmann Series 15300 RTMR** contains 10 mini-relays and 20 mini blade fuses in an IP66 sealed enclosure:

```
          Bussmann 15300 Relay & Fuse Matrix (Internal Layout)
  +==================================================================+
  | Relays (R1 to R10 - Bosch Mini 5-Pin)                            |
  | [ R1: Ignition Main ]  [ R2: Precharge Aux ]  [ R3: Brake Lights]|
  | [ R4: Reverse Lamp  ]  [ R5: Low Beam Head ]  [ R6: High Beam   ]|
  | [ R7: Horn Relay    ]  [ R8: Wiper Motor   ]  [ R9: Coolant Pump]|
  | [ R10: Cabin Blower ]                                            |
  +------------------------------------------------------------------+
  | Fuses (F1 to F20 - Standard Mini Blade ATO/ATC)                  |
  | F1: VCU Keep-Alive (5A)     | F2: Ignition Run (10A)             |
  | F3: RealDash Cluster (5A)   | F4: Horn Circuit (15A)             |
  | F5: Left Low Beam (10A)     | F6: Right Low Beam (10A)           |
  | F7: High Beams (15A)        | F8: Turn / Hazard Circuit (10A)    |
  | F9: Brake / Reverse (10A)   | F10: Wiper Motor (15A)             |
  | F11: Washer Pump (5A)       | F12: Interior Dome Light (5A)      |
  | F13: Inverter Logic (5A)    | F14: BMS Logic Gateway (5A)        |
  | F15: Coolant Pump (10A)     | F16: Radiator Fan (15A)            |
  | F17: Cabin Blower Fan (15A) | F18: 12V Auxiliary Outlet (15A)    |
  | F19: AVAS Sounder (5A)      | F20: Spare / USB Ports (10A)       |
  +==================================================================+
```

---

## 4. Complete Wire Gauge Matrix & Standards

All low-voltage wiring uses **FLRY-B (Thin-wall PVC insulated copper automotive wire)** conforming to ISO 6722:

| Circuit Type | Wire Cross-Section | Max Continuous Current | Applications |
| :--- | :--- | :--- | :--- |
| **High-Voltage Traction** | $35.0\text{ mm}^2$ (AWG 2) | 250A cont. / 350A peak | Battery $\to$ Contactor $\to$ VESC Inverter $\to$ Motor |
| **Main 12V Feed** | $10.0\text{ mm}^2$ (AWG 8) | 50A | DC-DC Converter output $\to$ Bussmann Fuse Box Bus |
| **Aux High-Power** | $2.5\text{ mm}^2$ (AWG 14) | 20A | Cabin Blower, Radiator Fan, Horn, Wiper Motor |
| **Lighting Circuits** | $1.5\text{ mm}^2$ (AWG 16) | 12A | Headlights, Tail/Brake Lamps, Turn Signals |
| **Sensors & Controls** | $0.75\text{ mm}^2$ (AWG 18) | 7A | Contactor coils, Relays, Switched inputs |
| **CAN Bus & Analog Signals** | $0.50\text{ mm}^2$ (AWG 20) | 3A | CAN Bus (twisted pair 33 twists/m), 0–5V Throttle |

---

## 5. Grounding Topology (Zero Ground-Loops)

```
        +-----------------------------------------------------------+
        |                 CHASSIS STEEL TUBULAR FRAME               |
        +-----------------------------+-----------------------------+
                                      |
                     [ Massive M10 Copper Star Lug ]
                                      |
                 +--------------------+--------------------+
                 |                                         |
     [ Clean Signal Ground ]                     [ High-Current Ground ]
     - Isolated sensor returns                   - 12V Battery Negative Buffer
     - VCU Analog Shielding                      - DC-DC Converter Negative
     - CAN Shield Drains                         - Blower, Wiper, Horn Returns
```

- **Safety Invariant:** High-voltage traction negative ($72\text{V}-$ DC) is **NEVER connected to the vehicle chassis frame**. It is strictly floating. Any leakage to the chassis $> 100\text{ k}\Omega$ triggers the Bender isolation fault relay, immediately dropping main contactors.